15.03.2010
We would like to present our new development – a load cell with a standard analog output. This is a “two-in-one” device that includes a load cell and a calibrated amplifier. The calibrated amplifier board is built into the load cell case and is secured.
This cost-effective solution simplifies connection of the load cell to standard data collection devices and process control systems – controllers, data input boards, etc.
Specifications:
- Output 4… 20 mA, 0… 5V
- Accuracy class according to GOST 30129 (OIML R60): С1
- Quantity of verification intervals: 1000
- Combined error, % of rated output: ≤±0.040
- Temperature effect on minimum dead load output, % of rated output /˚С: ≤±0.0028
- Temperature effect on rated output, % of rated output /˚С: ≤±0.0022
- Power supply voltage +12... 15V DC
- Compensated temperature range, ˚С: -10... +40
- Operating temperature range, ˚С: -30... +50
- Load cell material: stainless steel
- Protection level according to GOST 14254: IP68
The following option - standard analog output 4... 20mA / 0... 5V – is available for the following load cells: Т2, Т4, М50, М65, М70К, М100, МV150 и МV. The time of manufacture is 30 days.
Cable outlet scheme
Green: +U pit
Black: –U pit
White: +U signal (4... 20 mA/0... 5 V)
Red: –U signal